Author |
Message |
boomer
New member Username: boomer
Post Number: 1 Registered: 01-2008
| Posted on Monday, January 28, 2008 - 01:45 pm: |
|
Hi all Im looking for a wiring diagram for a volvo penta MD1 with a dyno start. I see a previous post here being a novice Im not too sure I'll interpret it correctly. Im more of a visual learner (i.e. pictures) than a read and comprehend type Any help greatfuly recieved |
adsum
New member Username: adsum
Post Number: 1 Registered: 01-2008
| Posted on Monday, January 28, 2008 - 02:35 pm: |
|
There is a wiring diagram in the manual of MD1B that is available in PDF-format at: http://www.volvo.com/volvopenta/global/en-gb/marine_leisure_engines/parts_servic e/publication_search/publication_search.htm |
boomer
New member Username: boomer
Post Number: 2 Registered: 01-2008
| Posted on Tuesday, January 29, 2008 - 05:28 am: |
|
that exactly what I needed. Thank you |
Eugenio Visitor
| Posted on Thursday, July 31, 2008 - 05:14 pm: |
|
Hi all, does anyone have a Volvo Penta MD1b engine for sale? Maybe in Europe? Thank you Eugenio |
tbower21
Visitor
| Posted on Friday, July 15, 2011 - 01:57 pm: |
|
Hi there, I am looking for the electrical drawings/schematics on the Volvo Penta D6-310A-B. |
eric
Member Username: eric
Post Number: 23 Registered: 03-2006
| Posted on Sunday, October 13, 2013 - 06:58 am: |
|
Any one got a regulator for a Bosch dynastart on an MD1? with wiring diagram if possible.. |
nobby
Advanced Member Username: nobby
Post Number: 34 Registered: 12-2005
| Posted on Tuesday, October 15, 2013 - 10:42 am: |
|
Your best bet would be to put together a separate regulator and solenoid combination. I would recommend the following regulator and their data sheet has a wiring diagram: http://www.dynamoregulators.com/dvr2-s.php Solenoid - Wire that was going to 50 on original regulator now goes to one side of the new solenoid coil the other side of the coil goes to ground. The wire that was going to B+/30 (Main Positive Supply) on the original regulator now goes to one side of the switched contacts the other side of the switched contacts goes to 30 on the dynastart. Regulator Brown - Ground Regulator Yellow - DF on Dynastart Regulator Blue - D+ on Dynastart and indicator Light Regulator Red - +ve supply attach this to what was B+/30 positive supply to the solenoid contacts. D- on dynastart is common to the casing and is ground this sometimes used to supply negative to the regulator negative terminal 31 and hence if you wish can be how the new regulator brown wire gets its ground. Cheers Nobby |